ระบบจอดรถอัตโนมัติ แบบ VERTICAL TOWER TYPE (YKVT-SYSTEM)

  • 752.png

Parking system that automatically transports a vehicle through a carrier to allow it to move vertically in a fixed parking zone with multiple layers
It is usually called ‘parking tower’ and suitable for middle and large buildings and buildings only for parking.

Specifications
Type VERTICAL TOWER TYPE
Available Vehicle 5,160L x 2,160W x 1,550(1,900)H 2,200kg / Equus or smaller
Movement MOTOR 22kW ~ 55kW, SPEED 60 ~120m/min
Power AC380V x 3Ø x 60Hz
Door 2,500W x 1,850(2,000)H
Operating Type TOUCH SCREEN
Safety System Inverter control type, human detector, simple car guidance device, fall prevention sensor, emergency stop switch, and various safety sensors, etc.

Front bottom type (Embedded, stand-alone)

vertical_tower_type02
(IS) : SEDAN, (R) : RV
Total height = PIT + Entry floor + Upper-side hangar floor + Overhead + Machinery room
1,200+2,100(S) or 2,400(R) + (1,610(S) or 2,100(R) x Number of levels) + 2,500 +1,800
※ In case of a stand-alone type, 500 mm (roof panel) above the machinery room should be additionally secured.
Four ventilation windows in the machinery room (1000 x 1000) should be secured. (At least two ventilation windows should be secured in the direction of the hoisting motor.)

*( ) is the size of the inner width of a standalone type.

Front center type (Embedded, stand-alone)

vertical_tower_type03
Total height = Top + Bottom (IS) : SEDAN, (R) : RV
Top = Entry floor + Upper-side hangar floor + Overhead + Machinery room
2,100(S) or 2,400IR) + (1,610(S) or 2,100(R) x 단수/Number of levels) + 2,500 +1,800
Bottom = Upper floor of the bottom + Lower-side hangar floor + PIT
2,100(S) or 2,400(R) + (1,610(S) or 2,100(R) x 단수/Number of levels) +1,200
※ In case of a stand-alone type, 500 mm (roof panel) above the machinery room should be additionally secured.
Four ventilation windows in the machinery room (1000 x 1000) should be secured. (At least two ventilation windows should be secured in the direction of the hoisting motor.)

*( ) is the size of the inner width of a standalone type.

Side bottom type (Embedded, stand-alone)

vertical_tower_type04
(IS) : SEDAN, (R) : RV
Total height = PIT + Entry floor + Upper-side hangar floor + Overhead + Machinery
1,200 + 2,100(S) or 2,400(R) + (1,610(S) or 2,100(R) x 단수/Number of levels)+2,500 +1,800
※ In case of a stand-alone type, 500 mm (roof panel) above the machinery room should be additionally secured.
Four ventilation windows in the machinery room (1000 x 1000) should be secured. (At least two ventilation windows should be secured in the direction of the hoisting motor.)

*( ) is the size of the inner width of a standalone type.

Side center type (Embedded, stand-alone)

vertical_tower_type05
Total height = Top + Bottom (IS) : SEDAN, (R) : RV
Top = Entry floor + Upper-side hangar floor + Overhead + Machinery room
2,100(S) or 2,400IR) + (1,610(S) or 2,100(R) x 단수/Number of levels) + 2,500 +1,800
Bottom = Upper floor of the bottom + Lower-side hangar floor + PIT
2,100(S) or 2,400(R) + (1,610(S) or 2,100(R) x 단수/Number of levels) +1,200
※ In case of a stand-alone type, 500 mm (roof panel) above the machinery room should be additionally secured.
Four ventilation windows in the machinery room (1000 x 1000) should be secured. (At least two ventilation windows should be secured in the direction of the hoisting motor.)

*( ) is the size of the inner width of a standalone type.

Front bottom coalition type
(Embedded, stand-alone)

vertical_tower_type06
(IS) : SEDAN, (R) : RV
Total height = PIT + Entry floor + Upper-side hangar floor + Overhead + Machinery
1,200+2,100(S) or 2,400(R) + (1,610(S) or 2,100(R) x 단수/Number of levels) + 2,500 +1,800
※ In case of a stand-alone type, 500 mm (roof panel) above the machinery room should be additionally secured.
Four ventilation windows in the machinery room (1000 x 1000) should be secured. (At least two ventilation windows should be secured in the direction of the hoisting motor.)

*( ) is the size of the inner width of a standalone type.

Front center coalition type
(Embedded, stand-alone)

vertical_tower_type07
Total height = Top + Bottom (IS) : SEDAN, (R) : RV
Top = Entry floor + Upper-side hangar floor + Overhead + Machinery room
2,100(S) or 2,400IR) + (1,610(S) or 2,100(R) x 단수/Number of levels) + 2,500 +1,800
Bottom = Upper floor of the bottom + Lower-side hangar floor + PIT
2,100(S) or 2,400(R) + (1,610(S) or 2,100(R) x 단수/Number of levels) +1,200
※ In case of a stand-alone type, 500 mm (roof panel) above the machinery room should be additionally secured.
Four ventilation windows in the machinery room (1000 x 1000) should be secured. (At least two ventilation windows should be secured in the direction of the hoisting motor.)